Digital work orders Training Vehicle Electric

Practical assignments (basic) 8 h 44 min, (advanced) 16 h 26 min, (specialist) 4 h 38 min; Fault assignments (basic) 2 h 21 min, (advanced) 6 h 59 min, (specialist) 7 h 48 min

Electude

Demo module - try it out now!


The practical training aid is a prepared vehicle, equipped with numerous measuring points on important components. This course covers 22 switchable faults of the training vehicle.

Volkswagen e-up! (basic), 14 h 02 min
After completing the basic practical Volkswagen e-up! assignments you are able to: Identify the different components of the Volkswagen e-up!, Point out the location of the different components of the Volkswagen e-up!, Charge the Volkswagen e-up! via a wall socket connection, Identify and specify the common charging errors of the Volkswagen e-up!, Identify the features of the Volkswagen e-up! components, Calculate and set the remaining charging time of the Volkswagen e-up!, Apply the steps used with a guided diagnosis of a Volkswagen e-up!

Preliminary theory with Volkswagen e-up! (basic), 2 h 57 min*
  • Working on hybrid vehicles
  • Working with voltage
  • Electric drive
  • Forms of drive
  • Fully electric car
  • HV cables
  • Charging
  • Charging modes
Practical assignments with Volkswagen e-up! (basic), 8 h 44 min
  • Volkswagen e-up!: Recognise and identify
  • Volkswagen e-up!: Charging via a wall socket
  • Volkswagen e-up!: HV system - Drive
  • Volkswagen e-up!: HV system - Comfort
  • Volkswagen e-up!: HV system - Charging
  • Volkswagen e-up!: Charging time calculation
  • Volkswagen e-up!: Guided fault finding
Fault assignments with Volkswagen e-up (basic), 2 h 21 min
  • Volkswagen e-up!: Fault 1
  • Volkswagen e-up!: Fault 3
  • Volkswagen e-up!: Fault 5

Volkswagen e-up! (advanced), 32 h 53 min
After completing the advanced practical Volkswagen e-up! assignments you are able to: Identify the function of the DC/DC converter in the Volkswagen e-up!, Identify the construction of the HV battery with the Volkswagen e-up!, Use the live-data parameters of the HV battery of the Volkswagen e-up!, De-energise the Volkswagen e-up! according to the procedure, Work with safety signs for the Volkswagen e-up!, The components in the Volkswagen e-up! that are part of the interlock system, Identify the connections of the charging connection of the Volkswagen e-up!, Identify the different charging methods and modes of the Volkswagen e-up!, Analyse the proximity pilot charging connection of the Volkswagen e-up!, Analyse the control pilot charging connection of the Volkswagen e-up!, Identify the components for the climate control of the Volkswagen e-up!, Apply the steps taken with a Volkswagen e-up! guided diagnosis

Preliminary theory with Volkswagen e-up! (advanced), 9 h 28 min*
  • Working with voltage
  • Electric drive
  • Voltage free switching HV system
  • Switching HV system to voltage free - software
  • HV battery
  • Battery balancing
  • Battery Management System
  • DC/DC converter
  • DC/DC converter - operation
  • Enabling HV system
  • Interlock
  • Charging connector
  • Charging cable
  • Charger
  • Charging station
  • Charging protocol
  • Charging system
Practical assignments with Volkswagen e-up! (advanced), 16 h 26 min
  • Volkswagen e-up!: De-energising
  • Volkswagen e-up!: HV battery
  • Volkswagen e-up!: DC/DC converter
  • Volkswagen e-up!: Climate control
  • Volkswagen e-up!: Interlock system part A (power supply)
  • Volkswagen e-up!: Interlock system part B (Pilot line)
  • Volkswagen e-up!: Charging system overview
  • Volkswagen e-up!: Proximity Pilot charging system
  • Volkswagen e-up!: Control Pilot charging system
  • Volkswagen e-up!: AC/DC charging system
  • Volkswagen e-up!: Guided fault finding
Fault assignments with Volkswagen e-up! (advanced), 6 h 59 min
  • Volkswagen e-up!: Fault 2
  • Volkswagen e-up!: Fault 4
  • Volkswagen e-up!: Fault 6
  • Volkswagen e-up!: Fault 12
  • Volkswagen e-up!: Fault 13
  • Volkswagen e-up!: Fault 14
  • Volkswagen e-up!: Fault 17
  • Volkswagen e-up!: Fault 18
  • Volkswagen e-up!: Fault 19

Volkswagen e-up! (specialist), 17 h 12 min
After completing the specialist practical Volkswagen e-up! assignments you are able to: Check the Volkswagen e-up! potential equalisation cables, Work with a milliohm meter and perform a 4-wire measurement, Check the insulation monitoring of the Volkswagen e-up!, Identify the function of the inverter in the Volkswagen e-up!, Explain how the different modes of the inverter work, Understand the way of determining the position of the electric motor in the Volkswagen e-up!, Analyse the operation of the Volkswagen e-up! position sensor, Apply the steps in a Volkswagen e-up! guided diagnosis

Preliminary theory with Volkswagen e-up! (specialist), 4 h 46 min*
  • Working with voltage
  • Inverter
  • Rotating magnetic field
  • Permanent magnet synchronous motor
  • Synchronous motor with permanent magnet - operation
  • Permanent insulation monitoring
Practical assignments with Volkswagen e-up! (specialist), 4 h 38 min
  • Volkswagen e-up!: Determining electric motor position
  • Volkswagen e-up!: Permanent insulation monitoring
  • Volkswagen e-up!: Guided fault finding
Fault assignments with Volkswagen e-up! (specialist), 7 h 48 min
  • Volkswagen e-up!: Fault 7
  • Volkswagen e-up!: Fault 8
  • Volkswagen e-up!: Fault 9
  • Volkswagen e-up!: Fault 10
  • Volkswagen e-up!: Fault 11
  • Volkswagen e-up!: Fault 15
  • Volkswagen e-up!: Fault 16
  • Volkswagen e-up!: Fault 20
  • Volkswagen e-up!: Fault 21
  • Volkswagen e-up!: Fault 22

License: You purchase a license for any number of students and teachers with a period of validity of 10 years. This can be extended individually after. The software will be activated on your Electude e-learning domain.

* Separate license may apply for the Preliminary theory.

Manufacturer:
Category: Digital work orders
Item number: 79406102
EQF-Level‍: Level 2Level 3Level 4
E-Learning‍: Electude
Keyword‍: E-Mobility